Versione ItalianaEnglish version

HORIZONTAL SCRUBBER 2 STAGE TREATMENT HR-2® SERIES

TYPE OF EQUIPMENT:
Horizontal with 2 levels of filtering.

OPERATING PRINCIPALS:
Pollutants in the air treated by the ecochimica® SCRUBBER are absorbed by chemical reaction through washing with reducing reagents. The horizontal scrubbers produced by Ecochimica® are double-stage to ensure greater efficiency and to guarantee emissions within ever more restrictive legal standards. Ecochimica® can manufacture three-stage horizontal scrubbers on request.

First stage (acid):
The intake air is washed on a large static contact surface (air and wash solution), passing horizontally over the capturing components sprinkled from above with an acidic solution with a pre-determined pH. The air then passes through demisters (blades which separate droplets), which remove excess reagent before passing on to the second stage, avoiding liquid carry-over.

Second stage (basic + oxidant):
Air from the first stage is washed a second time with the same process, with an oxidant in a basic solution with a predetermined pH and oxidation-reduction potential. The air then goes through appropriate demisters before passing on to the third stage.

 

LEGEND for HR-2® series
DE DEMISTER I UNTREATED AIR INTAKE SV TANK DISCHARGE
CV VISUAL LEVEL CONTROL MH INSPECTION PORT TP TOO FULL
EP ELECTRIC AIR WASHING PUMP QE ELECTRIC PANEL U SCRUBBED AIR OUTLET
FP CHEMICAL EXCHANGE PACKS QI HYDRAULIC PANEL VS FILSCRUBBER TANKTER

 

SIZE TABLES for HR-2® series • DRAWING n°: 2006000700
MODEL HR 500 HR 1500 HR 3000 HR 6000 HR 10000 HR 15000 HR 20000 HR 25000 HR 30000 HR 40000 HR 60000 HR 70000 HR 90000
DIMENSION A 3500 3900 4600 5000 5800 6000 6000 6800 7000 6800 7200 7200 7800
DIMENSION B 1000 1000 1000 1300 1500 1800 2200 2400 2400 3300 3400 3400 3500
DIMENSION H 1800 1800 1800 2200 2600 2700 2800 3400 3600 3800 4100 4800 5700

The constant technical improvements ecochimica applies to its equipments enables it to offer continuously improving products, thus making the technical data in its catalog non-binding.

    Request for Proposal.
Series:
Name - Surname*
Company*
Email*
Telephone
Fax
Total airflow to clean m3/h
Temperature °C:
Pollutants origin:
Pollutants and concentrations IN mg/m3
Concentrations OUT mg/m3
  * required field.